Three Phase UPS, Capacity 160000VA/128000W, PF 0.8, Input Voltage 3 x 380/400 VAC, Output Voltage 3 x 380/400 VAC, Backup Time 4 Minutes

Rp. 784.800.000

Baterai
  • Battery Type and Numbers : 12VDC x 32 Pcs (29-32 pcs adjustable)
  • Nominal Battery Voltage : 384 VDC (Based on 32pcs Batteries)
  • Charging current (max) : Default 10A; Max : 40A, 5A full load
  • Charging Voltage : 432 VDC ( Based on 32 pcs Batteries)
Voltase Keluar
  • Output Voltage : 3 x 380VAC/400VAC (3Ph + N)
  • Precision : Stationary : 1%; Transitory : +- 5% (load Variations 100-0-100%)
  • Frequency Range : 50/60 Hz Synchronized +- 1%; with main absent +- 0.1 Hz
  • Max Synchronized Speed : +- 1Hz/s
  • Current Crest Ratio : 3:1
  • Harmonic Distortion : <= 3% Thd (Linear Load); <= 5% Thd (Non-Linear Load)
  • Waveform (Battery Mode) : Pure Sinewave
  • Total Harmonic disortion (THDv) : <2% (Linear Load); <5% (non linear load)
  • Dynamic recovery time : 3 cycles at 90% of the static value
  • Admissible Overload : 110% for 10 min; 150% for 60 sec; > 160% for 200ms
  • Admissible Crest Factor : 3:1
  • Admissible Power Factor : 0.6-1 (inductive capacitive)
  • Imbalance Output voltage @ 100% unbalanced load : <1%
  • Total Harmonic disortion (THDv) : High Overload, short circuit : RMS voltage limit; High crest factor curent; Peak voltage limit
Voltase Masuk
  • Nominal Voltage : 3 x 380 VAC/400VAC
  • Acceptable Voltage Range : 285-485VAC
  • Frequency Range : 50/60 Hz +- 10%
  • Power Factor : 0.8
Daya Keluar 160000VA/128000W
Back-Up Time Full Load 4 minutes
Form Factor Tower
Lain-lain
  • Static bypass : Type : Solid state; Voltage : 380 VAC/400VAC (3Ph+N); Frequency : 50/60Hz; Activation Criterion : microprocessor control; Transfer Time : zero; Admissible overload : 150% for 1 Hour; 180% for 30 sec; > 200% for 200ms; Transfer to Bypass : Immediate for overloads above 160%; Retransfer : Automatic after alarm clear
  • Maintenance Bypass : Type : without interruption; Voltage : 380VAC/400VAC (3Ph+N); Freuency : 50/60 Hz
  • Overall Efficiency : Line Mode : 94%; Battery Mode : 94%
  • ECO Mode (Non-Parallel Models)
  • EPO Function
  • Standard : IEC 61000-4-5 Protein surge
  • Operating Temperature : 0-35 C continuous running, 40 C 8-hour running at nomial input voltage, recharging batteries and no overload, 45 C derating to 85% with linear load
  • Humidity : 0-90% (non-condensing)
  • Noise Level : Less Than 70dBA 1 Meter
Antarmuka / Interface
  • Modbus RS-232/RS485
  • Dry Contact
  • Optional SNMP